Commercial roof flashing failures and repairs

Most commercial roof leaks start at a flashing: where the membrane turns up a wall, wraps a curb, meets the roof edge or seals around a pipe. Here's how each kind of flashing fails, and what a roof leak repair that lasts looks like.

What is flashing, and where is it on your roof?

The field of a low-slope roof is a flat, continuous sheet, and it's rarely where water gets in. Everywhere the roof meets something that isn't roof, it needs a flashing: a piece of membrane or sheet metal that seals the transition.

  • Base flashing: membrane turned up from the roof onto a wall, parapet or curb.
  • Counterflashing: metal that laps down over the top of the base flashing so water can't run behind it. It's set into the wall or fastened to its face.
  • Termination bars: metal bars fastened along the top edge of base flashing and sealed above.
  • Edge metal: gravel stops, drip edges and fascia that finish the perimeter and hold the membrane down at the edge.
  • Penetration flashings: pipe boots, pitch pans filled with sealant, and flashings at vents, conduit and supports.
  • Curb flashings: around rooftop units, skylights and roof hatches.
  • Expansion joints: covers that let separate parts of a building move without tearing the roof.

Even a modest office building or condo roof has long runs of flashing and a long list of penetrations. Each one is a place where water can find a way in.

Illustration of a three-story office building with a flat roof, two rooftop units, rows of windows and a front entrance.
Every wall, edge, curb and pipe on a roof like this one needs its own flashing.

Why do flashings fail first?

Flashings are where roof waterproofing has the hardest job. Materials change, angles are tight, movement concentrates and sealant does real work there. The causes we find most often:

  • Shrinkage. Aging EPDM shrinks and pulls away from walls and curbs. You'll see the membrane bridging the corner at the base of a wall instead of lying tight in it, then tearing.
  • Dried-out sealant. Pitch pans, termination bars and counterflashing joints depend on sealant. High-altitude sun dries it out faster than at sea level. Flashings on south-facing parapets and around reflective rooftop equipment take the hardest exposure.
  • Movement. Walls, decks and rooftop units move differently with temperature, and units vibrate. Every freeze-thaw cycle in a Front Range winter works at your terminations and sealant joints.
  • Flashings that end too low. A recover or added insulation raises the roof surface, and flashings that once were tall enough now stop just above it. Snow drifts against the wall or a pond forms, and water rides over the top.
  • Wind at the edges. Chinook winds along the foothills and thunderstorm gusts on the plains pull hardest at corners and perimeters. Loose edge metal lifts, and the membrane peels back behind it.
  • Hail. Hail cracks pipe boots, dents edge metal and splits flashings that have stiffened with age.
  • Other trades. New penetrations for HVAC, solar or telecom work, cut and sealed by someone who isn't a roofer.
  • The original install. Missing corner patches, unsealed laps and base flashing that was never fully adhered all fail early.

What are the signs of flashing failure?

On the roof

  • Base flashing pulled away from the wall, wrinkled or open at inside and outside corners
  • Sealant cracked, shrunken or missing above termination bars and at counterflashing joints
  • Termination bars or counterflashing loose, bent or rusted
  • Edge metal lifted, loose at joints or dented
  • Pipe boots cracked or split, and pitch pans with the filler shrunk away from the pipe

Leave the looking to a trained crew. Most low-slope commercial roofs have unprotected edges, and flashings sit right at them.

Inside the building

  • Stains along exterior walls, or in a line under a parapet
  • Leaks near columns under rooftop units, skylights or hatches
  • Leaks that appear only in wind-driven rain, or during snowmelt when drifts sit against a wall

How is each flashing failure repaired?

A lasting roof flashing repair rebuilds the detail with materials that match your roof system. Sealant alone is almost never the fix.

FailureTypical repair
Base flashing pulled away or shrunkRemove it and rebuild with new membrane, fully adhered to the wall, with added securement at the base of the wall
Open lap or corner on TPO flashingClean, prepare and reweld, or weld in a new corner or patch, as long as the membrane still takes a reliable weld
Open lap or corner on EPDM flashingClean, prime and apply new flashing tape or membrane, with sealant at the edges
Loose termination bar or dried sealantRemove, clean, refasten and reseal, and add counterflashing over exposed terminations
Failed counterflashingReset or replace the metal and reseal it at the wall
Cracked pipe bootReplace the boot, or flash the pipe with new membrane flashing
Shrunken pitch panClean and refill it, or replace it with a prefabricated flashing where the penetration allows
Loose or damaged edge metalRefasten or replace it with tested edge metal, stripped in to the membrane
Flashing too lowExtend the flashing, or raise curbs and walls at replacement
Split or brittle expansion joint coverReplace it with a new flexible joint cover tied in to the membrane on both sides

On TPO, most flashing repairs are welded. On older TPO we run test welds first; a membrane that won't take a reliable weld says something about its remaining life. On built-up roofs, base flashings at parapets dry out, slump and pull away from the wall. We usually rebuild them with new reinforced flashing plies that are compatible with the existing roof.

On metal roofs, you'll usually see the trim, closures and penetration flashings fail long before the panels do. On spray foam roofs, we cut out damaged foam and coating at drains, edges and penetrations. Then we rebuild and recoat it so the surface stays continuous.

If water has been getting in at a flashing for a while, the insulation around it is likely wet. A lasting repair replaces that wet insulation too. An infrared moisture survey shows you how far it reaches.

Repair, re-flash or replace?

  • Repair when the failure is local and the rest of the roof is sound.
  • Re-flash when the field of the roof is in good shape but flashings everywhere are aging. Rebuilding base flashings, counterflashing, pipe boots and pitch pans as one project can add useful life to a roof that isn't ready to replace.
  • Replace when the membrane itself is near the end of its life or the insulation is widely wet. Re-flashing a worn-out roof spends money on details that will come off with it.

What doesn't work on flashings?

  • Mastic over everything. Asphalt roof cement doesn't bond well to TPO or EPDM, it can harm some membranes, and it makes the proper repair harder later.
  • Caulk where a termination belongs. A bead of sealant can't hold base flashing up a wall by itself.
  • Penetrations cut by other trades. They're a common way manufacturer warranties get voided. Before anyone cuts a new hole in a warranted roof, call the roofer who holds the warranty.

How do you keep flashings sound?

Flashing problems are cheap to fix while they're small. The NRCA recommends inspecting low-slope roofs at least twice a year and after severe weather.

On our S.M.a.R.T. maintenance program visits, we check seams and flashings section by section. In fall, we reseal the details that depend on sealant after summer UV has dried them out. That's before freeze-thaw opens them further. Every visit ends with a written report with photos.

Flashings at parapets and rooftop units have their own guides: parapet wall and coping leaks and leaks around rooftop HVAC curbs. For the bigger picture, see why commercial roofs leak and how the source is found.

If a flashing is leaking now, call us first at (720) 296-0000 or report a leak. To have your flashings checked before they leak, request an inspection. Whatever your roof system, we can repair its flashings; see our commercial roofing section. We work across the metro and along the foothills, including commercial roofing in Lakewood, where chinook winds are hardest on roof edges.

Our estimating is led by Andrew Rickert, our Operations Manager. He's a CPA with a Class-A general contractor license and has been with Truman since 2009. Meet him and the rest of our team.

Roof flashing FAQs

What's the difference between base flashing and counterflashing?

Base flashing is membrane turned up from the roof onto a wall or curb. Counterflashing is metal that laps down over the top of it, so water running down the wall can't get behind the base flashing.

Can you just reseal our flashing?

Sometimes, if only the sealant has failed and the flashing itself is sound and tight to the wall. If the flashing is pulled away, cracked or too low, sealing over it won't last, and it needs to be rebuilt.

Why does the flashing at one rooftop unit keep failing?

There are four usual causes. The unit may vibrate, or the curb may be too short for the roof height. A missing cricket can leave water ponding against it. Or service traffic may be damaging it. A repair that lasts fixes that cause, not just the flashing.

Will a flashing repair affect our roof warranty?

A repair can affect your warranty. Many manufacturer warranties require you to use an authorized contractor and report leaks promptly. We check the warranty's requirements before we work on a warranted roof.

Can flashing be repaired in winter?

Many repairs can be made on dry days. Adhesives, primers and sealants have temperature limits. So we may schedule larger rebuilds for a warmer stretch and make a temporary repair in the meantime.

Denver & 30 miles around

Get a straight answer about your roof

Tell us about the building. We'll inspect it, document what we find with photos, and give you options in writing: repair, restore, maintain or replace.

  • Commercial, HOA and multifamily roofs
  • Written, photo-documented findings
  • Insurance and association claim support

Prefer to talk? (720) 296-0000

Request a flashing inspection

We reply within one business day.

Call Report a leak Free inspection